LED step profiles with different lighting effects for professional step and stair-edge lighting
← Products & Systems
Custom lengths · 12/24 V DC · 24 V standard

LED step profiles for theatres, auditoriums and premium venues.

SL1, SL2, SLR, SLD and BL – five profile families for different lighting effects, floor finishes and installation situations.

Compare the five systems directly. Bissinger Lights configures lengths, LED technology, cable exits, connectors, power supplies, dimming, DMX/DALI integration and backup operation around the project.

5 profile families Project-specific lengths DMX / DALI capable Engineered and coordinated in Germany
Select by construction and lighting effect

Five profiles. Five clearly different applications.

The profile should follow the architecture – not the other way round. Start with step geometry, flooring and the required light effect.

360°
Interactive views available SL1, SL2, SLR and SLD can be rotated directly in the browser.

Which direction fits your step?

These five starting points cover the main applications. If your architectural detail falls between them, we assess the construction and develop the most suitable project solution.

Bestseller Surface-mounted · clear edge line

SL1 Clear illuminated step edge

The classic solution when the front edge of the step needs a clearly visible linear light line.

SL1 LED step profile with illuminated stair edge
Ideal for New-build and refurbishment projects requiring a straightforward visible edge line.
Type Surface-mounted
Geometry 80.7 × 42.8 mm
Light Edge line
360° View SL1 interactively Rotate the profile
Slim profile · limited installation space

BL Compact illuminated edge

A slim solution for limited build-up, special edge details, radii and refurbishment of older Tubelight installations.

Slim BL LED step profile with illuminated stair edge
Ideal for Refurbishment and special situations where a conventional full-size profile would be too large.
Geometry 53.5 × 20.5 mm
Standard 24 V DC
Option COB
Technical drawings

Compare the physical profile geometry before detailing the step.

The dimensions below describe the standard profile geometry. The final project detail also needs to consider flooring, fixing, cable exits, connectors and available installation space.

SL1 · standard geometry

Surface-mounted profile for a clearly visible linear step-edge light.

Width 80.7 mm
Height 42.8 mm
System standard 24 V DC
Light effect Step edge
Technical drawing of the SL1 LED step profile
Technical drawing SL1 · Final fixing, cable exit and project length are confirmed before fabrication.

SL2 · two-zone geometry

Surface-mounted profile with one light zone at the step edge and an additional downward-directed zone.

Width 80 mm
Height 42.5 mm
Light zones 2
Standard 24 V DC
Technical drawing of the SL2 LED step profile
Technical drawing SL2 · Electrical configuration of the two light zones is defined for the individual project.

SLR · floor-finish interface

Profile for coordinated carpet or linoleum installation with two illuminated lines.

Width 68 mm
Height 42.8 mm
Installation area 50.1 mm
Light lines 2
Technical drawing of the SLR LED stair nosing profile
Technical drawing SLR · The floor-finish cut-out and transition to the profile should be coordinated early.

SLD · downlight geometry

Low-profile solution with the light source directed downwards.

Width 81.28 mm
Height 35.2 mm
System 24 V DC
Direction Downlight
Technical drawing of the SLD LED downlight step profile
Technical drawing SLD · Standard mechanical profile dimensions.

BL · compact geometry

Slim step-edge profile for limited installation space and selected refurbishment applications.

Main width 53.5 mm
Total height 20.5 mm
System standard 24 V DC
Option Standard / COB
Technical drawing and dimensions of the BL LED stair nosing profile
Technical drawing BL · The current datasheet remains decisive for final project-specific dimensions and configuration.
Planning note: The profile drawing defines the mechanical geometry. Power supplies, circuit allocation, dimming, cable lengths, DMX/DALI integration and backup operation are coordinated separately as part of the complete project system.
Direct comparison

Choose by construction and light effect – not just by profile size.

This table provides the first orientation. Final LED configuration, cable exits and system interfaces are confirmed for the project.

Profile Geometry Installation Light effect Typical application
SL1 80.7 × 42.8 mm Surface-mounted Clear edge line New build & refurbishment
SL2 80 × 42.5 mm Surface-mounted Edge + downward light Very dark auditoriums
SLR 68 × 42.8 mm Floor-finish detail Two light lines Carpet / linoleum
SLD 81.28 × 35.2 mm Surface / partial recess Downlight Restrained architecture
BL 53.5 × 20.5 mm Compact edge profile Linear edge light Limited space & refurbishment
Not sure which profile fits the step construction? Send the section, photo or seating plan. We can compare the profile families against the real architectural detail.
Send project data
Beyond the profile

A profile becomes valuable when the complete system works.

Bissinger Lights coordinates the selected profile with the architectural detail, required light effect and electrical system.

  • Project-specific lengths
  • Light colour and LED version
  • Cable exits and connectors
  • Power supplies and circuits
  • DMX / DALI integration
  • Backup operation
International projects

Engineered and coordinated by Bissinger Lights in Germany.

For projects outside Germany, the prepared step-lighting package can be integrated by the appointed local installation contractor. Technical interfaces and responsibilities are coordinated with the project team.

  • System configuration
  • Connection information
  • Circuit allocation
  • Control interfaces
  • Technical documentation
  • Project integration support
Realised projects in Germany

Large installations prove how the profile performs as part of the system.

Profile selection, system technology and installation detail need to work together under real operating conditions.

Cinema · SL1 LED step lighting at IMAX Traumpalast Leonberg

IMAX Traumpalast Leonberg

Clear step-edge marking in a large-format cinema auditorium with integrated seat-row indicators and DMX operation.

approx. 450 m SL1 DMX Backup operation
Theatre · SL2 SL2 LED step lighting at Metronom Theatre Oberhausen

Metronom Theatre Oberhausen

SL2 with edge and downward lighting, coordinated with theatre operation, DMX and backup capability.

384 m SL2 two light zones DMX
Multiplex · SLR SLR LED step profiles at UCI Luxe East Side Gallery Berlin

UCI Luxe East Side Gallery Berlin

Modernisation of the existing SLR installation while retaining the available wiring infrastructure.

approx. 1,800 m 24 V DC refurbishment
FAQ

Practical questions about LED step profiles.

Which profile is best for a theatre or auditorium?
There is no single best profile for every project. The correct choice depends on step geometry, floor finish, available installation space, the required light effect and the operating conditions of the venue.
Are the profiles manufactured to project-specific lengths?
Yes. Lengths, cable exits, connector leads and grouping can be prepared according to the project quantities and installation sequence.
Can SL1, SL2, SLR, SLD and BL be dimmed?
The lighting systems can be designed for dimmed operation. The required dimming range and suitable components depend on LED configuration, load, cable lengths and control system.
Can the profiles be integrated with DMX or DALI?
Yes. DMX and DALI can be integrated depending on the project. Power supplies, dimmers and circuits are coordinated with the intended stage-lighting, house-light or building-control concept.
Can the system operate from backup power?
Backup operation can be engineered where required. This does not automatically mean that the step lighting fulfils a regulated emergency-lighting function. Applicable requirements are clarified with the responsible electrical and life-safety planning team.
Can a local contractor install the profiles outside Germany?
Yes. Bissinger Lights can configure and supply the system for integration by the appointed local installation contractor. Interfaces, documentation and responsibilities are coordinated with the project team.
Project enquiry

Choose the profile around the auditorium – not the auditorium around the profile.

Send us the step detail, section, seating plan or photos. We will identify the most suitable profile direction and coordinate the system around the required light effect.

Useful for the first review

Step section, approximate lengths, quantities, floor finish and required lighting effect.

Technical information if already known

DMX/DALI interface, power concept, existing wiring and requirements for backup operation.

No finished specification required

We can start with the information currently available.