Refurbishment & retrofit · Bissinger Lights

Modernise existing step lighting without replacing more than necessary.

What can stay and what needs to change? We assess the existing profiles, cabling, power supplies and controls, define a suitable refurbishment approach and coordinate the new components with the existing installation.

Specialist since 2017 Bissinger Lights
Industry experience since 2009 Step-lighting projects and existing installations
Engineering · supply · integration One technical contact for the system
Your existing installation

Not everything needs to be replaced.

Is the lighting failing, are steps difficult to see, or is the auditorium being refurbished? We first assess which parts of the existing system can reasonably remain. From there we determine whether individual components, the controls or the complete step-lighting system should be renewed.

Individual sections remain dark?
Identify the cause before replacing components unnecessarily.

The light is too bright, distracting or insufficient?
Assess light output, position and dimming together.

New seating, flooring or an auditorium conversion?
Adapt the lighting to the changed steps and construction.

Targeted replacement

Replace electrical components

If profiles and installation conditions remain suitable, we assess whether LEDs, power supplies or control technology can be renewed while retaining other parts of the system. Existing and new components must be technically compatible.

Controls & power →
At the step edge

Retrofit LED step profiles

Where the step edge needs to become more visible, we assess a suitable profile against the existing floor finish, fixing conditions and required lighting effect.

Compare step profiles →
Recessed into the construction

Integrate a flush light line

Where the lighting should be integrated into a step, platform or stage edge, we assess whether the existing material and available installation depth allow the required recess.

View recessed lighting →

You do not need to select a product first. Describe what no longer works or what is changing. We will identify which refurbishment direction fits the existing installation.

Existing-system check · free PDF

What can stay? What needs to be checked?

Refurbishing step lighting is not only about selecting a new profile. Existing cabling, power supplies, dimmers, controls, circuit structure and backup operation can determine how much of the original installation can reasonably remain.

Existing Step Lighting Refurbishment Checklist

Use the PDF for an initial technical review or during an on-site survey. It records the information, photographs and measurements that are particularly useful before an existing step-lighting system is modified.

  • Existing profiles, step construction and fixing
  • Existing cabling: conductor count, size and cable length
  • 24 V power supplies and identification labels
  • PWM dimmers, DMX, DALI and existing controls
  • Backup or emergency-power integration
  • Circuit grouping, photographs and measured values
Download the refurbishment checklist

6 pages · for theatres, cinemas, auditoriums and other professional step-lighting installations.

Refurbishment checklist (PDF) →
Our approach

Understand the existing installation first. Then define the new system.

The existing step geometry, floor finish, cable routes, power supply and control system all influence what can reasonably be retained. Refurbishment is therefore treated as a system task, not simply as a profile replacement.

Work with the existing construction

Step build-up, flooring, cable routes and control technology are considered before components are selected. For existing cabling we also consider conductor count, conductor size, cable length, connected load and voltage drop.

Retain usable infrastructure

Suitable cable routes, circuits, controls or power supplies do not need to be replaced simply because the lighting system is being modernised. Their suitability is checked against the requirements of the new system.

Coordinate the interfaces

Bissinger Lights coordinates the step-lighting system with the electrical installation and other relevant trades. Technical support remains available after supply and integration.

Process & cost

From the first photograph to a defined refurbishment scope.

You do not need a finished specification to start. We identify which information is still needed before a technical solution and quotation can be prepared.

01

Show the existing situation

Describe the problem and send available photographs, drawings or approximate dimensions. Where useful, use the refurbishment checklist to record cabling, power supplies, controls and identification labels.

02

Define what can remain

We assess profiles, cabling, power supplies, circuits and controls and identify what can be reused and what should be renewed. Additional measurements can be defined if required.

03

Receive a defined quotation

Material and agreed services are calculated from the clarified scope so the intended work is transparent before the order.

04

Implement the agreed solution

We supply the configured system for installation by the appointed contractor. Depending on location and scope, installation or commissioning support can be agreed separately.

What determines refurbishment cost? Key factors are the number and length of steps, reusable components, accessibility, existing cabling, power distribution, control technology and the agreed installation scope.

Integration according to project needs

Bissinger Lights can coordinate the system. Your local team can integrate it.

Projects with Bissinger Lights installation support

Depending on project location and scope, agreed installation or commissioning services can form part of the project. Responsibilities, interfaces and timing are defined before work begins.

Supply for the appointed local contractor

Where the local electrical or fit-out contractor carries out the installation, we coordinate the supplied components and provide technical information for the agreed interfaces. Additional on-site support can be discussed separately.

Before making a decision

Common questions about refurbishing existing step lighting.

Can existing cables and profiles remain?

We assess their condition, dimensions and technical suitability. For cables, relevant factors include conductor count, conductor size, cable length, supply arrangement and electrical load. For profiles, construction and compatibility with suitable lighting components matter.

Is the existing cabling suitable for new LED step lighting?

That depends on conductor count, conductor size, cable length, the number of connected steps and the electrical load of the new system. RGB systems or separately controlled light zones may require more conductors and significantly more current. Existing cabling can often remain for low-power 24 V monochrome systems if current capacity and voltage drop are suitable.

Is there a checklist for surveying an existing system?

Yes. The Existing Step Lighting Refurbishment Checklist can be used for an initial technical assessment or during an on-site survey. It covers profiles, cabling, 24 V power supplies, dimming, DMX, DALI, backup operation, circuit grouping, photographs and measured values.

Open the refurbishment checklist (PDF)

Does the auditorium need to be closed during the work?

That depends on the project scope and the work required on site. The implementation can be coordinated with operating schedules and available refurbishment windows. Whether areas can be treated in phases is clarified during planning.

Can systems from another manufacturer be refurbished?

We can assess whether existing components remain usable or whether a replacement solution is more appropriate. Photographs of profiles, connections, power supplies, control equipment and identification labels are particularly helpful. Compatibility with third-party components can only be confirmed after review.

What happens to dimming, DMX, DALI or backup operation?

Existing interfaces, supply conditions and the required operating behaviour are considered during refurbishment. Backup-operation requirements are coordinated with the responsible project and electrical planning. Backup capability alone does not make step lighting a statutory safety-lighting system.

What information do you need for an initial enquiry?

A short description and available photographs are enough for the first contact. An overview of the auditorium and a close-up of a typical step are particularly useful. If available, add dimensions, approximate step quantities, cable information and photographs of power-supply or control-equipment labels.

Your next step

Show us what needs to change.

Send a short description of the existing installation through the contact page. Photographs or drawings can be included. We will clarify the sensible refurbishment scope and the technical next steps with you.

  1. What is the problem? Failures, poor lighting effect, refurbishment or retrofit.
  2. What already exists? Profiles, cabling, power supplies, controls, photographs or drawings where available.
  3. Where and when? Project location and preferred timeframe if already known.